Emulex ONECONNECT OCE10102-F Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Sítě Emulex ONECONNECT OCE10102-F. Emulex ONECONNECT OCE10102-F User guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - ETERNUS DX

FUJITSU StorageETERNUS DXConfiguration Guide -Server Connection-(FCoE) for VMware® ESXDriver Settings for Non-Fujitsu Converged Network Adapter CardsP

Strany 2

The following shows an example of this.Host name Server#1IP Address 192.168.0.10Physical slotnameConverged Network Adaptercard WWNInstance name Physic

Strany 3 - December 2014

If multiple Converged Network Adapter cards are already installed in the server at the time of pur-chase, the one-to-one relationship between the WWN

Strany 4

2 Enter the number of the Converged Network Adapter card for which SAN Boot is to be set and press the[Enter] key.------------------------------------

Strany 5 - Table of Contents

4 Select "Enable" and press the [Enter] key.-------------------------------------------------------------------------------

Strany 6 - Chapter 1

6 Select "Configure Boot Devices" and press the [Enter] key.-------------------------------------------------------------------------------

Strany 7

8 A list of the WWPNs and recognized LUNs (as device names) of the connected ETERNUS DX400 series isdisplayed. Input the number of the device that is

Strany 8

11 Set the "Boot number". Select the boot device startup method (via WWPN or via DID), and change thesetting.Input "Boot this device vi

Strany 9

1.2.3 Installing VMware ESX•VMware ESX should be installed now if it has not yet been installed in the server. Refer to the followingURL for details.h

Strany 10

*1: Recommended value = 512 ¸ (number of FCoE ports that are connected to a single CA port) ¸number of LUNs(Round the result down)Use the value of &qu

Strany 11 - 1.2.2 Setting Up SAN Boot

1.2.4.2 For VMware vSphere 5.1 or 5.01 Record the module name for the Converged Network Adapter card that is loaded into VMware ESXi.The underlined po

Strany 12 - [Enter] key

This page is intentionally left blank.

Strany 13 - BIOS is now enabled

Use the following command to change the setting values when the driver parameter name is"lpfcX_lun_queue_depth", the number of I/Os is "

Strany 14

In the following example, the number of ports is "two" since "4" and "5" (two underlined portions) aredisplayed as the S

Strany 15

Chapter 2 Setup Procedure for QLogic Converged NetworkAdapter CardsThis chapter describes how to set up the VMware ESX server and driver when connecti

Strany 16

Setting Up Converged Network Adapter Card DriverPerform the settings for the Converged Network Adapter card driver.•"2.2.5 Setting Up the Converg

Strany 17 - 1.2.3 Installing VMware ESX

2.2 Setting Up the Converged Network Adapter CardsThis section describes how to set up the server with the QLogic Converged Network Adapter cards desc

Strany 18 - 5 Reboot VMware ESXi

The procedure is as follows:1 Install the Converged Network Adapter card in the server.For the installation method, position (PCI bus slots), and note

Strany 19 -

7 Perform the BIOS settings for the Converged Network Adapter card.Check the parameter values in the [Adapter Settings] window against those in the fo

Strany 20 - 1.2.4.3 For VMware vSphere 4

(2) Select the Converged Network Adapter card to be set (BIOS setting) in the [Select Host Adapter]window.The [Fast!UTIL Options] menu appears. Then p

Strany 21 - 6 Reboot VMware ESX

4 Check the values for each parameter.Selectable Boot SettingsSelectable Boot:(Primary) Boot Port Name, Lun: Boot Port Name, Lun: Bo

Strany 22 - Adapter Cards

8 Select [Reboot System] and press the [Enter] key.Exit Fast!UTILReboot SystemReturn to Fast!UTILThe server reboots.To return to the [Fast!UTIL] menu,

Strany 23

PrefaceThis manual briefly explains the operations that need to be performed by the user in order to connect anETERNUS DX to a server running VMware®

Strany 24

2.2.5 Setting Up the Converged Network Adapter Card DriverChange the parameters for the Converged Network Adapter card driver.2.2.5.1 For VMware vSphe

Strany 25 - QLE8142 5800 05 04 00 2

This option cannot be individually applied to each port on the Converged Network Adapter card.All ports on the target Converged Network Adapter card

Strany 26

When the value for this setting is changed, refer to "FUJITSU Storage ETERNUS DX ConfigurationGuide -Server Connection- (FCoE) for VMware® ESX&q

Strany 27 - Return to Fast!UTIL

2 Check the default value for the Converged Network Adapter card.Specify the module name for the Converged Network Adapter card that you recorded in S

Strany 28 - Select Host Adapter

Appendix A WWN Instance Management Table for the Server(Blank)This table is used for setting up the Converged Network Adapter cards. Utilize this tabl

Strany 29 - 2.2.4 Installing VMware ESX

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-(FCoE) for VMware® ESXDriver Settings for Non-Fujitsu Converged Network Adapter Card

Strany 31 - 2.2.5.2 For VMware vSphere 5

The Contents and Structure of this ManualThis manual is composed of the following two chapters and an appendix.•"Chapter 1 Setup Procedure for Em

Strany 32 - 2.2.5.3 For VMware vSphere 4

Table of ContentsChapter 1 Setup Procedure for Emulex Converged Network Adapter Cards 61.1 Workflow ...

Strany 33 - 5 Reboot VMware ESX

Chapter 1 Setup Procedure for Emulex Converged NetworkAdapter CardsThis chapter describes how to set up the VMware ESX server and Converged Network Ad

Strany 34 - Appendix A

Setting Up Converged Network Adapter Card DriverCheck the default setting values and number of ports for the Converged Network Adapter card, and setup

Strany 35 - (FCoE) for VMware

1.2 Setting Up the Converged Network Adapter CardsThis section describes how to set up the VMware ESX server for use with the Emulex Converged Network

Strany 36

3 Enter the number of the Converged Network Adapter card that is to be checked and press the [Enter]key.Example:--------------------------------------

Komentáře k této Příručce